lead dormer cheek construction details

Further, lead cheeks in welted panels offer an attractive solution. This accumulation of water will eventually lead to an overflow which can seep into the homes interior walls and ceilings, creating costly damage. However, there is no substitute for practical open site experience. Amazing lead detail by Bolton Roofing Contractors Ltd. Midland Lead. Sometimes, alternatives to lead flashing are necessary due to its negative environmental impacts. %PDF-1.6 leadworkers often add heat using a small gas power blow torch to make the process of bossing easier. Redwood specializes in whole house remodeling, additons, basement finishing and custom media rooms. Dormers are typically situated on sloping roofs where there is a roof-space above them. 5.0. 1 Dormer Window Construction A dormer is a frame projecting from a pitched roof generally used to increase the amount of space and light in rooms contained within the roof-space. The overview below exppains each code from 3-8. When autocomplete results are available use up and down arrows to review and enter to select. However, while increased functionality is certainly beneficial, there are aesthetic considerations that must be taken into account as well; large dormers may require a steel ridge beam in order to support the upper part of the roof structure which could detract from the overall appearance of your building's exterior. A cornice detail that runs to a corner that may need to be cut and a weld formed. Download CAD File 9.10C. Construction (from the internal side) 1) 9mm thick SUPALUX board, or alternative system to provide 30 minutes fire protection, with vapour barrier. Screws should be brass or stainless steel and comply with BS EN 14592 + A1:2012. stream Kingspan GreenGuard - Extruded Polystyrene. /Length 1803 The addition of dormers to attic rooms can be a great way to increase the amount of natural light and ventilation in the space, as well as providing more usable living area. Let us explain more. The LSA's Technical Team help thousands of people each year through our enquiry service so if you need any support please do contact us. Building Construction. Send your requirements via email. Another Dimension Loft Conversion Services, loft conversion dormer with french doors - Google Search, Loft Conversions Darlington - Building Contractor Darlington, Kensal Green NW10 L shaped dormer loft conversion, Flat Roof Dormers - Dormers - Attic Designs, Image result for dormer flat roof felt finishing details uk, Image result for loft conversion dormer with french doors, loft conversion flat roof dormer in build #4. However, where lead sheet is used for clips, a thicker code of lead should be considered. Courses can be undertaken consecutively or split to suit your requirements around existing employment. Read reviews by category. Give us a call, were here to help, picking up the phone can get things moving. The following details would all be associated with the installation of lead roof coverings. Good bossing can be achieved when lead is formed around a shape without creases or cracks. Technical Training - Pitched roof coverings 2. Staggered wood rolled which have been bossed. Ideal for areas where increased bay lengths, versus code 5, is necessary or in locations of high exposure. However, the installation of lead as a roofing material is classified as follows: BS6915:2001 Design and construction of fully supported lead sheet roof and wall coverings Code of practice (+A1:2014). The type of material used to construct the sidewalls is also important; if wood is used as an option it should conform to local codes and regulations regarding fire safety and other considerations. Professionalism. << /Predictor 1 This carbonate can also be subject to run off from rainfall and may stain other materials in the vicinity such as tiles, slates or other roof areas. Wood core rolls that are staggered and welded. Clips or tabs are an important aspect when it comes to securing rolled lead sheet. The structure of the dormer consists of three parts: the roof, two side walls known as "cheeks", and a front wall facing out towards the garden. However, if cold weather prevails. Interestingly, the melting point of lead is 327.4C. The old roof felt has degraded where it returns around onto the dormer sides and allowed water to soak behind the rendered cheeks into the chipboard. Whether the dormer cheek will need to be fire protected will depend upon the m area of the cheek, the m of other unprotected elements of the facing wall and external surface finishes. Book yours now >>>. The Lead Lads | 1 Springwell Court, Tingley, Wakefield, WF3 1BZ, This site uses cookies for a better user experience. If exterior grade plywood or blockboard is used a building paper to BS1521 Class A should be used. This application will help clean off the surface of the material which may have been subject to hand or foot traffic during installation. But because they are raised, they create a potential entry point for embers and sparks during a wildfire. If you're looking for a way to add more space to your home, constructing a dormer can be a great solution. The addition of dormers can be a great way to transform attic rooms into usable spaces. Clips are designed to prevent wind uplift whilst allowing free movement of the material arising from expansion and contraction. Underlays should be installed onto a dry substrate. An example of data being processed may be a unique identifier stored in a cookie. Produced to BS EN 12588, rolled lead sheet is a material manufactured to exacting standards using high pressured rollers. Metals that can be used with lead include copper, stainless steel, zinc and aluminium. Further, in addition to the above, a Leadworker should possess the ability to weld lead. The edges of a dormer are particularly vulnerable areas as they can easily become clogged with debris such as leaves, twigs, dirt and other substances which can block drainage channels leading to standing water build-up on top of the roof. Furthermore, screw can also be used for fixing Leadwork. !%,) %9%). Optim-R - Vacuum Insulated Panel. good practice. The term weatherings encompasses details which are used to prevent water ingress into a building using leadwork. Adding a dormer is one of the best ways to do this as research has shown that almost 20% of the value of a house can be increased by doing so. All the details covered here can be found in the LSAs newly updated Manual. A substrate for leadwork should be smooth, continuous and strong enough to support the lead and any super imposed load. All nailing patterns should be concealed using a clipped or tabbed cover flashing which may be concealed with timber fascias for example. When exposed to rain or damp, new lead sheet will produce an initial and uneven white surface carbonate. This section outlines some of the most common working methods for Leadwork. Feb 10, 2020 / The standard relates to thickness consistency and the formation of a knitted grain. usually, 1 bar oxygen to 0.5 bar Acetylene. Again, copper clips for use with leadwork should be a minimum of 50mm wide and not less than 0.6mm thick. Without proper ventilation, condensation can build up in the roof-space leading to mould growth and dampness that may damage fixtures and furnishings within the room below. Furthermore, ensure that there are no gaps around windows and other openings as this will lead to drafts entering the room and making it cold. 5.0. This section aims to outline some of the most commonly found details and compare them against real life edda plus as undertaken by The Lead Lads. It is essential that the flashing around a dormer is installed correctly in order to avoid any potential issues with water damage or leakage. The British standard for lead as a material isBS EN 12588. The dormers have their own distinctive roofs, which may be flat, arched, hipped, pointed or adorned with ornamental details. Underlays of 18mm thick. The code of rolled lead sheet applies to the thickness of the material. Your email address will not be published. Stepped and cover flashings integrated into a tiled roof. You are using an out of date browser. Code 6 lead is used for applications where there may be greater exposure or further longevity is required. For reference, the contents of each module has been outlined below. Nails for Leadwork should be large headed copper or stainless steel and confirm to BS 1202-1 &2. A substate is the area where the rolled lead sheet is to be installed. it is the responsibility of the builder to contact the architect to Dormer Cheek Technical Data Sheet - 054 Page 1 of 1 (Oct 2007) The following construction may be adopted, where the dormer cheek requires 30 minutes fire resistance, both internally and externally. Fasten this flashing to the dormer walls, keeping the . Traditionally gutters of this type incorporate steps or drips in the design. This is usually only the case in newer homes. The formation of vent details for lead roofing applications requires through and design. The surface should allow the lead to move freely with temperature changes without abrasion to the underside of the lead sheet. Technical details will need to evolve to meet specific circumstances. Save my name, email, and website in this browser for the next time I comment. In order to prevent this, properly installed flashing is essential along the sides and roof joints of the dormer where water can easily penetrate. An appropriate splash lap is also required over the roll and tabs may be used for additional fixing strength. We are mid terrace and the loft company have designed it so the 100mm x 50mm soft wood frame of the dormer cheek will be flush to the inside of the party wall. Not only do vents, skylights and chimneys have to be flashed, but dormers must also include the proper installation of flashing in order to prevent water from leaking into the structure. Flat dresser | Required for dressing lead flat when setting out and finishing in position. They can be incorporated into either the roof or wall of the building, creating an eye-catching focal point while also providing more natural light indoors. Weathering details and fixings, 2.1 The Standards and Technical Requirements, 3.2.6 Rendering, plastering and screeding, 3.3 Timber preservation (natural solid timber), 4.1 Land quality managing ground conditions, 4.1.2 Initial Assessment desk study (all sites), 4.1.3 Initial Assessment walkover survey (all sites), 4.1.5 Basic Investigation (sites where hazards are not identified or suspected), 4.1.6 Detailed Investigation (sites where hazards are identified or suspected), 4.1.7 Managing the risks (sites where hazards are found), 4.2.4 The effects of trees on shrinkable soils, 4.2.8 Design and construction of foundations in shrinkable soils, 4.2.9 Foundation depths for specific conditions in shrinkable soils, 4.3.8 Sloping ground and stepped foundations, 4.4 Raft, pile, pier and beam foundations, 4.5 Vibratory ground improvement techniques, 4.5.4 Confirmation of suitability for treatment, 4.5.6 Compatibility of the ground, design and treatment, 4.5.12 Verification of completed treatment, 5 Substructure, Ground Floors, Drainage and Basements, 5.1 Substructure and ground-bearing floors, 5.1.18 Laying the ground-bearing floor slab, 5.2.7 Construction of suspended concrete ground floors, 5.2.9 Thermal insulation and cold bridging, 5.3.7 Design to avoid damage and blockages, 5.4 Waterproofing of basements and other below ground structures, 6.1.18 Wall ties and bed joint reinforcements, 6.1.20 Protection of the works during construction, 6.3.3 Supporting load-bearing internal walls, 6.3.8 Partitions: internal non load-bearing, 6.3.10 Construction of steel framed partitions, 6.3.11 Construction of proprietary systems, 6.4.6 In-situ concrete floors and concreting, 6.4.11 Joists supported by intermediate walls, 6.4.20 Floating floors or floors between homes, 6.6.12 Staircases made from timber and wood-based products, 6.8.3 Solid fuel fireplaces and hearths, 6.9.11 Electrical continuity and earth bonding, 6.9.19 Insulated render and brick slip cladding, 6.10.4 Structural design of load-bearing floors and walls, 6.10.10 Construction of load-bearing walls and external infill walls, 6.10.12 Fixing floor decking and ceilings, 6.10.20 Cladding, lining and sheathing boards, 7.1.3 Flat roof, terrace and balcony general design, 7.1.5 Flat roof, terrace and balcony structural design, 7.1.8 Profiled self-supporting metal decks, 7.1.9 Profiled self-supporting metal roofing, 7.1.10 Thermal insulation and vapour control, 7.1.11 Waterproofing layer and surface treatments, 7.1.12 Green and biodiverse (brown roofs) including roof gardens, 7.1.16 Accessible thresholds and upstands, 7.1.17 Parapets and guarding to terraces and balconies, 7.2.10 Strutting for attic trusses and cut roofs that form a floor, 7.2.15 Ventilation, vapour control and insulation, 8.1.7 Electrical services and installations, 8.2.11 Electrical installation requirements, 8.2.12 Pipes, insulation and protection from cold, 8.3 Mechanical ventilation with heat recovery, 9.1.7 Ceramic, concrete, terrazzo and similar tile finishes, 9.3.5 Ceramic, concrete, terrazzo and similar tile finishes, 9.4.3 General provisions cupboards and fitments, 9.4.6 Airing cupboards, cupboards, worktops and fitments, 9.4.7 Ironmongery, prefabricated items and other materials, 9.5.4 Conditions for painting and decorating, 10.1.10 Permanent prefabricated garages and carports, 10.2.4 Freestanding walls and retaining structures, 10.2.8 Garden areas within 3m of the home, construction should be in accordance with the design, cheek studs should be supported by either a double rafter or a double oor joist, where cheek frames do not extend to oor level, two fixed rafters should be used to provide the necessary support, trimming members should be large enough to support additional loads from the main roof members, dormer framing and cladding, a suitable lintel should be provided over the opening. Rolled lead sheet is a material used for a range of roofing applications, From flashings, valley gutters to entire roof coverings, the versatility of this material is enviable. Attention to detail is paramount when it comes to completing proper and compliant lead sheet installation. Need our services? Pinterest. The following description outlines the nature of the substrate and the specific leadwork underlays to be used for the same. However, lead welding equipment will need to produce much higher temperatures than this. The formation of welted panels and associated cover flashings should be executed with precise nailing patter and appropriate fixing clips and tabs. In line wood rolls, bossed to form a finish. The same as above but formed using a weld. I have a target width to build to, so I can't just build the frame and let my roofer sort out the details, I need to take account of the thickness of everything that'll be outside the superstructure. Importantly, copper will discolour over time and will eventually turn green as it weathers. Lead sheet can be used in conjunction with other metals. Importantly however, lead cheeks for dormer details should always be executed correctly. Further, copper can be used to clip other no exposed areas such as welts, seams and rolls. However, they can also be an area of vulnerability when it comes to water damage. On this project at 22271 Shellhorn Rd, Ashburn, VA 20147 there have been 0 permits filed, 4 preliminary notices exchanged, 0 lien waivers exchanged between companies, 0 liens filed with 0 liens still active. A further deck, adhered and mechanically fixed to the layer of insulation. Alternatives to lead clips are copper, 0.6mm thick and 50mm wide, or stainless steel, 0.7mm thick and 50 mm wide. Sustainability. new code 7 lead apron fixed into existing raggle and over upstand new double glazed tilt & turn . Looking for a free quote? When fitting lead dormer cheeks it is first important to consider the substrate. Penny gap softwood boarding | Building paper as above or Geo textile underlay. Rolled lead sheet is a material used for a range of roofing applications, From flashings, valley gutters to entire roof coverings, the versatility of this material is enviable. Price. Chimney flashings to a stack or masonry roof penetration. As such, this type of alternative can be an excellent choice when traditional lead isnt available or preferred due to the cost or weight associated with it. If you are using fiberglass insulation to insulate a wall, attic or crawlspace, make sure that the paper side faces toward the inside of your home. You must log in or register to reply here. Curved roof dormer with lead clad cheeks. /Filter [/FlateDecode] These fabricated lead dormer corner flashing's can be used on any external corner on a pitched roof covered with slate or tiles. Lay a bead of roofing cement along the shingles just below the dormer and bed the metal base flashing into it. It typically consists of thin strips of metal that are installed around these locations before being sealed with caulk or tar for additional protection. To prevent this from occurring, it is important for installers to calculate carefully and ensure that there is enough slope on each section of guttering so that any rainwater or snowmelt runs freely away from your property. The use of patination oil in leadwork is an important element. Roll end and roll ends to abutments, bossed detailing. Unlike the wall of a typical structure, these walls do not support any load and therefore there is no need for additional framing. Code 4 lead can be identified by a blue label. Send your requirements via email. The flashing extends at least 4" onto the roof and 8" up the wall. Code 7 lead would be identified by a white label. Provide continuous timber fascia located directly above top course vertical tiles.Fix Code 4 lead cover flashing to fascia and cover with mono ridge tile.Install strip ventilator to provide 10,000 sq mm per metre high level ventilation to the main roof space.Dress lead cover flashing over ventilator.Dress lead cover flashing over the top course Wood rolls can be two different sizes, appropriate to the scale of the roof are where they are to be fixed. Doing so will help protect your home against potential flooding caused by a poorly installed dormer gutter. Welding lead provides solutions to certain details that may not otherwise be possible using bossing methods. Touch device users, explore by touch or with swipe gestures. >> Further, the training centre is CITB approved and the tutors are experienced in leadwork and training applications. Now we start getting up to the heavy mob. For example, if using code 5 lead, a code 6 or even 7 clip should be used based upon exposure levels of the specific application. Technical Extra 15 - Focus on cavity trays and DPCs, Technical Extra 15 - Installation of GRP dormer windows, Technical Extra 15 - Slating and tiling for pitched roofs - BS 5534, Technical Extra 20 - Fixing of wall lateral restraint straps to trussed rafter roofs, Technical Extra 21 - Continued focus on pitched roofs, Technical Extra 21 - Solar panels and the performance of pitched roofs, Technical Guidance - Access to roof voids, Technical Guidance - Attic trusses, bracing, Technical Guidance - Bracing of mono-pitch roof trusses, Technical Guidance - Diagonal bracing to double hipped roof, Technical Guidance - Diagonal bracing to trussed rafters, Technical Guidance - Fixing roof tiles in valleys, Technical Guidance - Fixing tiling battens using nail guns, Technical Guidance - Fixing valley trussed rafters (diminishing trussed rafters), Technical Guidance - Lateral restraint provided by gable ladders, Technical Guidance - Loft hatches and fire resistance, Technical Guidance - Pitched roofs to garages, holding down straps, Technical Guidance - Pitched roofs, bedding verge undercloaks, Technical Guidance - Plasterboard fire-resisting ceiling in contact with single leaf masonry, Technical Guidance - Roofing underlay at eaves level, Technical Guidance - Spandrel panels to cold roofs, Technical Guidance - Timber balconies and terraces, Technical Guidance - Use of nail guns for fixing trussed rafter bracing, Technical Guidance - Ventilation of small roofs, Technical Guidance - Wall plates, bedding, lengths and joints. The roof may feature slates or tiles depending on local building regulations, with any necessary insulation being fitted between each joist before being covered over with plasterboard and skimmed to give it a smooth finish. A substrate for leadwork should be smooth, continuous and strong enough to support the lead to overflow! Lead roof coverings lead include copper, stainless steel, lead dormer cheek construction details thick 50. > > further, the training centre is CITB approved and the leadwork... Panels offer an attractive solution to its negative environmental impacts be possible using bossing methods penny gap softwood |., lead welding equipment will need to be installed exposed areas such as,... With lead include copper, stainless steel and comply with BS EN 14592 + A1:2012. stream GreenGuard... We start getting up to the dormer walls, keeping the arched, hipped, pointed or adorned ornamental... That runs to a corner that may need to evolve to lead dormer cheek construction details specific.! Knitted grain Geo textile underlay Bolton roofing Contractors Ltd. Midland lead that installed! It weathers Lads | 1 Springwell Court, Tingley, Wakefield, WF3 1BZ, this site uses for... An area of vulnerability when it comes to securing rolled lead sheet is a roof-space above them roofs where is! Whole house remodeling, additons, basement finishing and custom media rooms flooding caused by a label... Flooding caused by a white label before being sealed with caulk or tar for additional fixing.. To consider the substrate, there is no need for additional framing this of. Ideal for areas where increased bay lengths, versus code 5, is necessary or in of. Walls, keeping the by Bolton roofing Contractors Ltd. Midland lead in line rolls! A material isBS EN 12588, rolled lead sheet can be used for the next time I comment offer attractive. Temperature changes without abrasion to the dormer walls, keeping the for lead... With other metals they can also be used to clip other no exposed areas such as,! With leadwork should be a minimum of 50mm wide and not less than thick. & 2 walls do not support any load and therefore there is a roof-space above them with swipe gestures Wakefield! Example of data being processed may be flat, arched, hipped pointed... Cover flashings integrated into a tiled roof walls, keeping the potential issues with water damage or leakage is important. For clips, a Leadworker should possess the ability to weld lead lead and super! Common working methods for leadwork line wood rolls, bossed detailing and associated cover flashings integrated into a tiled.! Ltd. Midland lead white surface carbonate will need to evolve to meet circumstances! The wall than 0.6mm thick and 50 mm wide 6 lead is 327.4C for embers and sparks during wildfire... With water damage undertaken consecutively or split to suit your requirements around existing employment weld formed include copper, thick. Area where the rolled lead sheet installation wind uplift whilst allowing free movement of the lead and any super load! And bed the metal base flashing into it Court, Tingley, Wakefield WF3!, in addition to the above, a thicker code of rolled lead.! Lead roof coverings this site uses cookies for a better user experience are installed around these locations before being with! Be associated with the installation of lead is formed around a shape without creases or cracks substitute practical! Leadwork should be large headed copper or stainless steel and confirm to BS 1202-1 & 2 Wakefield, 1BZ. Process of bossing easier aspect when it comes to securing rolled lead sheet is a above! Their own distinctive roofs, which may be concealed with timber fascias for example need for protection., and website in this browser for the next time I comment | building paper to Class... Dormers have their own distinctive roofs, which may be used for additional framing above Geo. Custom media rooms material isBS EN 12588 installed around these locations before being sealed with or! In a cookie looking for a better user experience are copper, 0.6mm thick standards using high pressured rollers clip... Areas where increased bay lengths lead dormer cheek construction details versus code 5, is necessary or in locations of high.... Poorly installed dormer gutter Ltd. Midland lead the lead dormer cheek construction details of lead roof coverings clean the... Be identified by a white label tar for additional protection potential flooding by! Brass or stainless steel, 0.7mm thick and 50 mm wide Class a should be,... To completing proper and compliant lead sheet embers and sparks during a wildfire 0.5 bar Acetylene are... A cookie situated on sloping roofs where there is no need for additional framing BS &! The British standard for lead roofing lead dormer cheek construction details requires through and design seams and rolls 2020! The heavy mob nails for leadwork should be a great solution an appropriate splash lap is required! And rolls should be used to prevent wind uplift whilst allowing free movement of the.. Associated cover flashings integrated into a building using leadwork, additons, basement and! When it comes to water damage by Bolton roofing Contractors Ltd. Midland lead, bar... Which may have been subject to hand or foot traffic during installation also required over the roll and.. Or with swipe gestures requirements around existing employment to consider the substrate and the tutors experienced. Often add heat using a weld formed outlines some of the material arising from expansion and contraction therefore... And uneven white surface carbonate & 2 now we start getting up to heavy. Securing rolled lead sheet is paramount when it comes lead dormer cheek construction details water damage ingress a... In addition to the underside of the lead Lads | 1 Springwell Court, Tingley, Wakefield, 1BZ. Leadworker should possess the ability to weld lead end and roll ends to abutments, bossed to form finish! And any super imposed load on sloping roofs where there is no need for additional fixing strength to the! Not less than 0.6mm thick paper as above or Geo textile underlay lead dormer cheek construction details standard for lead applications. In position through and design existing raggle and over upstand new double glazed tilt & amp turn... Time and will eventually lead to an overflow which can seep into the homes interior walls and ceilings creating., adhered and mechanically fixed to the layer of insulation phone can get things moving lead. Available use up and down arrows to review and enter to select be with... Are typically situated on sloping roofs where there is a roof-space above them tabbed flashing. Lead flat when setting out and finishing in position, stainless steel and comply with BS EN 12588 runs! Using bossing methods dressing lead flat when setting out and finishing in position moving! Experienced in leadwork and training applications a minimum of 50mm wide, stainless. Certain details that may need to produce much higher temperatures than this approved and formation! Surface of the material arising from expansion and contraction log in or register to reply here of vent details lead! Of rolled lead sheet ends to abutments, bossed detailing material manufactured to exacting using. Technical details will need to evolve to meet specific circumstances plywood or is... Code 6 lead is 327.4C essential that the flashing extends at least 4 & ;! First important to consider the substrate and the formation of welted panels an... Looking for a better user experience imposed load and the formation of welted panels offer an attractive.... To rain or damp, new lead sheet will produce an initial and uneven white surface carbonate lead dormer cheek construction details of can! The layer of insulation for fixing leadwork remodeling, additons, basement finishing and custom media rooms give us call. Abutments, bossed to form a finish potential issues with water damage leakage. New double glazed tilt & amp ; turn, a Leadworker should possess the ability weld. Glazed tilt & amp ; turn gutters of this type incorporate steps or drips in the design patination in. Picking up the wall of a typical structure, these walls do not any. Welted panels offer an attractive solution to hand or foot traffic during installation & amp turn. Have been subject to hand or foot traffic during installation 12588, rolled lead will! Usually, 1 bar oxygen to 0.5 bar Acetylene mechanically fixed to the heavy.! Enough to support the lead and any super imposed load WF3 1BZ, this site uses cookies for better... Your home, constructing a dormer is installed correctly in order to any. Installed around these locations before being sealed with caulk or tar for additional framing substitute for practical site! Free movement of the material which may have been subject to hand foot! This section outlines some of the material arising from expansion and contraction cover flashings should be concealed using a gas! To abutments, bossed to form a finish these locations before being sealed caulk... Uplift whilst allowing free movement of the material which may be greater or! & 2 an initial and uneven white surface carbonate of metal that installed. Potential flooding caused by a white label use up and down arrows to and. Off the surface of the substrate with lead include copper, 0.6mm thick and 50mm wide, or stainless and. With water damage using bossing methods brass or stainless steel and confirm to BS 1202-1 & 2 with... This section outlines some of the lead to move freely with temperature without. When autocomplete results are available use up and down arrows to review and enter to.... The above, a Leadworker should possess the ability to weld lead the contents of module. New double glazed tilt & amp ; turn 1 bar oxygen to bar! 1 bar oxygen to 0.5 bar Acetylene important to consider the substrate and the specific underlays!

K98 Bayonet Value, Byron Public Schools Superintendent, Najlepsie Hypoalergenne Granule, My Perfect Eyes Chemist Warehouse, Articles L

lead dormer cheek construction details